Neighborhoods › Midtown South-Flatiron-Union Square › Building 1015420
Interior renovation: Interior tenant build-out on 6th floor including…, est. $2.9M
122 5 Avenue, Manhattan 10036 · Permit Entire
| Job | M01426617 (4 filings: I1, S1, S3, S2) · Alteration |
|---|---|
| Category | interior renovation |
| Estimated cost | $2,939,475 |
| Scale | 11 → 11 stories; 17,284 sq ft |
| Work types | General Construction |
| Filed | Aug 24, 2026 |
| Professional | Vocon |
| Building | BIN 1015420 · BBL 1008190039 |
| Official record | DOB NOW job M01426617 |
DOB description
M01426617-I1: Interior tenant build-out on 6th floor including installation of non-load bearing partitions, doors/frames, and related finishes. No change in use, egress or occupancy under this application. Filed in conjunction with ALT. 1 # 121208870.
M01426617-S1: Interior tenant build-out on the 6th floor including installation of new HVAC system and related ductwork/piping. No change in use, egress, or occupancy under this application.
M01426617-S3: Installation of full floor sprinkler coverage and relocate an auxiliary fire hose valve and to connect to existing base building combined sprinkler/standpipe system. No change in use, egress or occupancy under this application.
M01426617-S2: Interior tenant build-out on the 6th floor to include new plumbing fixtures and related piping. No change in use, egress or occupancy under this application.
Status timeline
- Aug 24, 2026 — New job filed (Permit Entire) M01426617-I1
- Aug 24, 2026 — New job filed (Permit Entire) M01426617-S1
- Aug 24, 2026 — New job filed (Permit Entire) M01426617-S3
- Sep 9, 2026 — New job filed (Permit Entire) M01426617-S2
- Sep 14, 2026 — Permit issued — work can start (General Construction) M01426617-I1
- Sep 15, 2026 — Permit issued — work can start (Permit Entire) M01426617-I1
- Sep 15, 2026 — Permit issued — work can start (Mechanical Systems) M01426617-S1
- Sep 16, 2026 — Permit issued — work can start (Permit Entire) M01426617-S1
- Sep 23, 2026 — Permit issued — work can start (Plumbing) M01426617-S2
- Sep 24, 2026 — Permit issued — work can start (Permit Entire) M01426617-S2
- Sep 28, 2026 — Permit issued — work can start (Standpipe) M01426617-S3
- Sep 28, 2026 — Permit issued — work can start (Sprinklers) M01426617-S3
- Sep 29, 2026 — Permit issued — work can start (Permit Entire) M01426617-S3
Work permits
| Permit | Work | Status | Issued | Expires |
|---|---|---|---|---|
| M01426617-S3-EW-SD | Standpipe | Permit Issued | Sep 28, 2026 | Feb 28, 2027 |
| M01426617-S3-EW-SP | Sprinklers | Permit Issued | Sep 28, 2026 | Feb 28, 2027 |
| M01426617-S2-PL | Plumbing | Permit Issued | Sep 23, 2026 | Mar 30, 2027 |
| M01426617-S1-MS | Mechanical Systems | Permit Issued | Sep 15, 2026 | Dec 31, 2026 |
| M01426617-I1-GC | General Construction | Permit Issued | Sep 14, 2026 | Dec 31, 2026 |
Watch this block
Get an email when the next job is filed within 100 ft of this address. Free, weekly.