NYC Permit AlertsBy BuildPermitGuide

Neighborhoods › Harlem (South) › Building 1053349

Interior renovation: Filed for interior & exterior renovations of existing…, est. $2.2M

222 Lenox Avenue, Manhattan 11201 · Plan Examiner Review

JobM00726001 (10 filings: A1, P1, P2, P5, P8, P7, P4, P9, P3, P6) · Alteration
Categoryinterior renovation
Estimated cost$2,197,972
Scale5 → 5 stories; 8 → 8 dwelling units; 6,826 sq ft
Work typesGeneral Construction
FiledSep 15, 2026
ProfessionalRomines Architecture Pllc
BuildingBIN 1053349 · BBL 1017200036
Official recordDOB NOW job M00726001

DOB description

M00726001-A1: FILED FOR INTERIOR & EXTERIOR RENOVATIONS OF EXISTING NON ELEVATOR PRIOR-TO-1968 CODE, CLASS 3-NFP MULTIPLE DWELLING AS PER PLANS FILED HEREWITH; NO CHANGE PROPOSED TO USE, EGRESS, OR OCCUPANCY.
M00726001-P1: FILED FOR INTERIOR & EXTERIOR RENOVATIONS OF EXISTING NON ELEVATOR PRIOR-TO-1968 CODE, CLASS 3-NFP MULTIPLE DWELLING AS PER PLANS FILED HEREWITH; NO CHANGE PROPOSED TO USE, EGRESS, OR OCCUPANCY.
M00726001-P2: FILED FOR INTERIOR & EXTERIOR RENOVATIONS OF EXISTING NON ELEVATOR PRIOR-TO-1968 CODE, CLASS 3-NFP MULTIPLE DWELLING AS PER PLANS FILED HEREWITH; NO CHANGE PROPOSED TO USE, EGRESS, OR OCCUPANCY.
M00726001-P5: PLUMBING WORK FILED IN CONJUNCTION WITH RENOVATION OF 5-STORY BUILDING: INSTALL NEW SANITARY, SANITARY VENT, DOMESTIC WATER DISTRIBUTION, NATURAL GAS AND DOMESTIC HOT WATER HEATING EQUIPMENT. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00726001-P8: PLUMBING WORK FILED IN CONJUNCTION WITH RENOVATION OF 5-STORY BUILDING: INSTALL NEW SANITARY, SANITARY VENT, DOMESTIC WATER DISTRIBUTION, NATURAL GAS AND DOMESTIC HOT WATER HEATING EQUIPMENT. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00726001-P7: BOILER INSTALLATION FILED IN CONJUNCTION WITH RENOVATION OF 5-STORY BUILDING. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00726001-P4: SPRINKLER WORK FILED IN CONJUNCTION WITH RENOVATION OF 5-STORY BUILDING: INSTALL A NEW AUTOMATIC WET SPRINKLER SYSTEM. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00726001-P9: SPRINKLER WORK FILED IN CONJUNCTION WITH RENOVATION OF 5-STORY BUILDING: INSTALL A NEW AUTOMATIC WET SPRINKLER SYSTEM. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00726001-P3: STRUCTURAL WORK FILED IN CONJUNCTION WITH RENOVATION OF 5-STORY BUILDING. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
M00726001-P6: MECHANICAL WORK FILED IN CONJUNCTION WITH RENOVATION OF 5-STORY BUILDING: PROVIDE NEW HVAC UNITS. NO CHANGE TO USE, EGRESS OR OCCUPANCY.

Status timeline

Work permits

PermitWorkStatusIssuedExpires
M00726001-S2-PLPlumbingPermit IssuedOct 7, 2026Jun 28, 2027
M00726001-S1-PLPlumbingPermit IssuedJun 17, 2026Jun 18, 2027
M00726001-S4-EW-SPSprinklersPermit IssuedJun 16, 2026Jan 19, 2027
M00726001-S5-BEBoiler EquipmentPermit IssuedJun 16, 2026Jun 17, 2027
M00726001-S3-MSMechanical SystemsPermit IssuedMay 26, 2026Mar 31, 2027
M00726001-S6-STStructuralPermit IssuedMay 10, 2026Mar 31, 2027
M00726001-I1-GCGeneral ConstructionPermit IssuedMar 22, 2026Mar 24, 2027

Map

Watch this block

Get an email when the next job is filed within 100 ft of this address. Free, weekly.