Interior renovation: Selective removals of existing: bulkhead…, est. $8.5M

108 Montrose Avenue, Brooklyn 10018 · Approved

JobB01339631 (11 filings: I1, P3, S1, P1, P2, S3, P4, S2, S6, P5, S5) · Alteration
Categoryinterior renovation
Estimated cost$8,500,000
Scale3 → 3 stories; 9,000 sq ft
Work typesGeneral Construction
FiledDec 25, 2025
ProfessionalVelocity Architectural Services Pll
BuildingBIN 3071199 · BBL 3030600001
Official recordDOB NOW job B01339631

DOB description

B01339631-I1: Selective Removals of Existing: Bulkhead (Doors/Frames), Metal Coping, Window A/C Units; Replacement of Existing Roof Coverings, Railings, Roof Drains, Louvers, Coping Stones/Flashing, New: Roof System, Railings, Bulkhead, Roof Drains, Insulated Windows
B01339631-P3: SELECTIVE REMOVALS OF EXISTING VENTILATORS, STEAM RADIATORS, AHU, 127 STEAM FINTUBE RADIATORS, EXHAUST FANS, ROOF MOUNTED CHILLER;, MECHANICAL UNIT INSTALLATION AS PER DESIGN PLANS SUMMARY OF WORK.
B01339631-S1: SELECTIVE REMOVALS OF EXISTING VENTILATORS, STEAM RADIATORS, AHU, 127 STEAM FINTUBE RADIATORS, EXHAUST FANS, ROOF MOUNTED CHILLER;, MECHANICAL UNIT INSTALLATION AS PER DESIGN PLANS SUMMARY OF WORK.
B01339631-P1: Selective Removals of Existing: Bulkhead (Doors/Frames), Metal Coping, Window A/C Units; Replacement of Existing Roof Coverings, Railings, Roof Drains, Louvers, Coping Stones/Flashing, New: Roof System, Railings, Bulkhead, Roof Drains, Insulated Windows
B01339631-P2: NEW STEEL DUNNAGE PLATFORM WITH SCREEN-WALL, SERVICE PLATFORM and STAIR ON ROOF. NEW STEEL FRAMING TO REINFORCE SLAB AROUND NEW SLAB OPENINGS, INFILL EXISTING SLAB OPENINGS.
B01339631-S3: NEW STEEL DUNNAGE PLATFORM WITH SCREEN-WALL, SERVICE PLATFORM and STAIR ON ROOF. NEW STEEL FRAMING TO REINFORCE SLAB AROUND NEW SLAB OPENINGS, INFILL EXISTING SLAB OPENINGS.
B01339631-P4: SELECTIVE REMOVALS OF GAS METER PIPING, HOT WATER HEATER, BOILER PILOTS, EXISTING CLASSROOM SINKS, ROOF DRAINS, ROOF VENTS AND INSTALL NEW HEAT PUMPS, TEMP ELECTRIC WATER HEATER, ROOF DRAINS, SUMP PUMP, VTRS, CLASSROOM SINKS.
B01339631-S2: SELECTIVE REMOVALS OF GAS METER PIPING, HOT WATER HEATER, BOILER PILOTS, EXISTING CLASSROOM SINKS, ROOF DRAINS, ROOF VENTS AND INSTALL NEW HEAT PUMPS, TEMP ELECTRIC WATER HEATER, ROOF DRAINS, SUMP PUMP, VTRS, CLASSROOM SINKS.
B01339631-S6: REMOVAL OF EXISTING TWO (2) 7500 GALLONS FUE OIL TANKS. REFER TO MECHANICAL FILING FOR REMOVAL OF FUEL OIL PUMPS, POWER CONNECTIONS, CONTROLS AND ANCILLARY EQUIPMENT.
B01339631-P5: Shutdown Entire Sprinkler System provide Fire Watch, Selective Removals of Existing Sprinkler Branch, Riser and 6 Sprinkler Heads, Install New Tamper Switches, Flow Switch, 2" Sprinkler Drain/Tie-In, New Inspector Test Connection.
B01339631-S5: Shutdown Entire Sprinkler System provide Fire Watch, Selective Removals of Existing Sprinkler Branch, Riser and 6 Sprinkler Heads, Install New Tamper Switches, Flow Switch, 2" Sprinkler Drain/Tie-In, New Inspector Test Connection.